Fujian Wide Plus Precision Instruments Co., Ltd.
Main products:Intelligent digital display instrument,paperless recorder,regulating valve,electromagnetic flow meter,gauge/differential pressure transmitter,quartz watch movement,Level Meter
Products
Contact Us
  • Contact Person : Ms. Deng Nichol
  • Company Name : Fujian Wide Plus Precision Instruments Co., Ltd.
  • Tel : 86-591-83975383
  • Fax : 86-591-83969600
  • Address : Fujian,FUZHOU,NO.1 CHA SHAN ROAD MAWEI HI-TECH DEVELOPMENT ZONE.
  • Country/Region : China
  • Zip : 350015

Intelligent high performance digital regulator

Intelligent high performance digital regulator
Product Detailed
Competitive price with high performance cost, high reliability... and pass ISO9001:2000, CE and the like certificates
Main technical parameters
Input signal

Analog quantity: ·thermocouple : standard thermocouple BSKERJT and so on                           ·Platinum resistance Pt 100                           ·Current: (0∼20) mA (4∼20) mA                           ·voltage: 1∼5 V,0∼5V

Output signal

analog quantity output ·DC 4∼20 mA, (load resistance ≤500Ω)relay output             ·max AC 250 V, 3A / 1A contact (when resistive load)voltage output         ·SSR drive DC 12V, load resistance above 800Ωcontrol output 1       ·proportional band: 0.1∼999.9 or 0.01∼99.99   ·integral time: 0∼3600 s(heating/cooling)     ·derivation time: 0∼3600s       ·control period: 1∼120 s                               ·lagging amplitude: 0.1∼100.0% or 0.01∼10.00%control output 2      ·proportional band: primary proportional band 0∼1000%(heating/cooling)    ·control period: 1∼120 s                               · dead zone / lapping: -100.0∼100.0 or 10.0∼10.0                               ·lagging amplitude: 0.1∼100.0% or 0.01∼10.00%

Characteristics

measuring accuracy   ·±0.5% FS ±1characterresolution                    · 1 (°F), 0.1 (except R and S) selected on parameter pictureDisplay mode              ·double screen digital displayControl/alarm              ·No.1 alarm: first alarm AL1 max. AC250V, 3A/1A contact (when resistive load)                                     ·No 2 alarm: second alarm AL2 max. AC 250 V, 3A/1A contact (when resistive load)                                                        heater break alarm: when select CT function, fit three-phase supply(current output cannot use)communication function   ·communication interface: RS485 communication (MODBUS communicated protocol)                                   ·transmitting output: DC (4∼20) mA or DC (1∼5) V                                  ·outer given switching: out connection switch input

Intelligent high performance digital regulator



Copyright Notice @ 2008-2022 ECVERY Limited and/or its subsidiaries and licensors. All rights reserved.